Installation and Programming Manual
50
ZONES: ZONE PARTITIONS
ZONES: ZONE TYPE
Quick Key Item Default Explanation
2 2
PARTITIONS
all zones
are
assigned
to
Partition 1
§ programs the Partition Assignment(s) for each zone
from this display, press [ENTER]
specify its two-digit Zone Number
press [ENTER] again
§ the “xx” in the Z=xx designation refers the number of
the zone currently being given a partition(s) assignment
§ when programming a zone’s partition assignment(s),
keep in mind that in a multi-partitoned system, a zone
may be assigned to more than one partition
§ a system “without” partitions is regarded as having a
single partition (i.e. Partition 1)
§ use the [STAY] key to toggle between YES (Y) or
NO (,), as to whether the currently-programmed zone
is assigned to the designated partition or use keys 1 to
8 to toggle partition status to YES (Y) or NO (,)
§ use either the [STAT] or [BYP] keys to move the
cursor left or right, respectively
2 3
Zone
Type
ZONE TYPE
---
§ programs the Zone Type for each zone; there are
20 Zones Types, each defined below
§ to program the Zone Type for any zone:
from this display, press [ENTER]
specify its two-digit Zone Number
press [ENTER] again, and select among the following:
00 Not Used --- § used to disable a zone
§ all unused zones should be given this designation
01 Exit/Entry 1
default for
Zone 1
§ used for entry/exit doors
§ if violated, zones given this designation will not cause
an intrusion alarm during the Entry and Exit Delay
periods specified under Exit/Entry 1 in the Time Define
section
02 Exit/Entry 2 ---
§ as above, except that Exit/Entry 2 time intervals apply
2 3 zz
+
E
N
T
E
R
03 Exit(OP)/Entry § used for an entry/exit door that, for convenience, may
be kept open during the disarmed period
§ such a zone behaves as described in Entry/Exit 1,
above, except that, if faulted at the time the system is
armed, it will be bypassed and NOT prevent system
arming
§ to avoid an intrusion alarm, however, it must be
secured before the expiration of the Exit Delay period
04 Entry Follower default for
Zone 2
§ usually assigned to motion detectors and to interior
doors protecting the area between the entry door and
the keypad
§ a zone(s) given this designation will cause an
immediate intrusion alarm when violated unless an
Entry/Exit zone was violated first
§ if so, an Entry Follower zone(s) will remain bypassed
until the end of the Entry Delay period
INSTALLER PROG:
2)ZONES ↓↓
2)PARTITIONS ××
Y.......
SUBJECT: ZONES
3)ZONE TYPE ××