Installation and Programming Manual
43
SYSTEM: SYSTEM CONTROL
Quick Key Item Default Explanation
SYSTEM CONTROL (cont’d)
1 2 14 Alarm ZE Cut NO
if YES: produces an alarm if the communication between the
panel and any Zone Expander is lost
if NO: no alarm will occur if the communication between the
panel and any Zone Expander is lost; however, the
system will produce a local trouble indication
1 2 15 Fire Temporal Pattern NO
if YES: during a fire alarm, the external sounder(s) will
produce a pattern of three short bursts, followed by a
brief pause between them
if NO: during a fire alarm, the cadence produced by external
sounder(s) will be a pattern of 2 seconds ON, then
2 seconds OFF
1 2 16 Code Grand Master NO
if YES: only the individual(s) with the Authority Level of Grand
Master can change all User Codes, along with the
TIME and DATE
if NO: besides the Grand Master, the individual(s) with the
Authority Levels of Master and Manager can change
their own User Code and all codes with a lower
Authority Level, along with the TIME and DATE
1 2 17 Audible Jamming
Not for UL
Installations
NO
• relates to the Jamming Time parameter (on page 40)
if YES: once the specified time is reached, the panel will
activate the external sounder and send a reporting
code to the Central Station if so defined (see page
89)
if NO: as above, except the external sounder will not operate
1 2 18 Technician Tamper NO
if YES: it will be necessary to enter the Installer Code to reset
a Tamper Alarm (indicated by a lit keypad Tamper
LED); thus, Tamper Alarm (and Tamper LED) resets
will require the intervention of the alarm company
if NO: a Tamper Alarm (and the resulting Tamper LED) is
reset by correcting the problem–requiring no alarm
company help
1 2 19 Technician Reset NO
if YES: it will be necessary to enter into the Installer Code to
make “READY” an alarmed partition after it’s been
reset, thus requiring the intervention of the alarm
company
§ NOT READY-TECH RESET will be displayed
on relevant LCD Keypads
§ note that before the READY LED can light, all
zones within the partition must be secured
if NO: once an alarmed partition is reset, the READY LED
will light when all zones are secured
1 2 20 Abort Alarm NO
if YES: and an alarm is sent in error, it will be possible for the
Central Station to also receive an “Abort Alarm” code,
sent subsequent to the initial Alarm Code, if a valid
User Code is entered to reset the alarm within 90
seconds after being initiated
if NO: no “Abort Alarm” code will be sent once an alarm has
been triggered
1 2 21 Summer/Winter Clock NO
if YES: the ORBIT-Pro will automatically set its Time of Day
clock one hour ahead in the spring (on the first
Sunday in April) to conform to USA Daylight Savings
Time and one hour back in the fall (on the last Sunday
in October) to conform to USA Standard Time)
if NO: no such accommodation is made
INSTALLER PROG:
1)SYSTEM ↓↓