Installation and Programming Manual
13
Wiring to External Sounders
External Sounders
BELL/S
+ –
Jumper J3
§ connect suitable wire to the external sounding device(s), whether a bell, an
electronic siren, or a loudspeaker
§ consider a larger wire gauge (e.g. 18-16) if the distance separating the
sounder(s) and the panel is significant; consider also the sounder’(s)s
current draw when choosing a suitable wire gauge
§ polarity must be observed for electronic siren(s) and/or polarized bells (if
used)
§ if an external sounder connection is not made, use a 2200 resistor in its
place to avoid potential sounder supervision problems
§ be sure to appropriately position the board's BELL/LS Jumper (J3), as
follows:
- if your external sounder is a Loudspeaker (without a built-in sound
driver), position jumper J3 so it covers both pins; doing so causes the
panel, if so programmed, to produce a continuous oscillating voltage
for burglary/panic alarms, and an interrupted oscillating voltage for fire
alarms
- if your external sounder is either a Bell or an Electronic Siren (equipped
with a built-in sound driver), position jumper J3 so it does NOT cover both
pins; as such, a steady 12 Volts DC is produced at the sounder terminals
during burglary/panic alarms; a slow, pulsing voltage is produced during a
fire alarm
Wiring to an
External, Triggerable
Device
Utility Output 1
AUX U01
+ –
§ wire these terminals to any device [e.g. the coil of a 12 VDC, 70 mA (max)
relay] which you want activated when Utility Output 1 is triggered (for
additional information, see the Utility Outputs section on page 63)
Telephone Line
Connections
(typically derived from an
installed RJ31X jack)
§ to the Main Board’s LINE terminals, connect the two wires (usually red and
green) from the RJ31X jack’s Direct Connect Cord, corresponding to the
incoming telephone line
§ to the Main Board’s SET terminals, connect the two wires (usually gray
and brown) from the RJ31X jack’s Direct Connect Cord, corresponding to
the premises’ phones
J2
DEFAULT Jumper
§ be sure the J2 Jumper is NOT placed over the two corresponding pins
§ place this jumper over a single pin to prevent its loss
GROUND
§ refer to the grounding suggestions, previously discussed on page 11
Flying Leads
RED and BLACK
§ have the Standby Battery handy (typically 12 VDC, 6 AH, typical)
but do NOT connect it at this time
AC
§ wire the output from a 16.5 VAC, 40 VA transformer to the Main Board’s
AC terminals
§ use the appropriate wire gauge (e.g. 18-16)
§ do NOT plug in the transformer at this time