User Manual
All rights reserved. No part of this document may be reproduced in any
form without prior written permission from the publisher.
5INWSAUM
© 8/2004 ROKONET Electronics Ltd.
www.rokonet.com
WisDom Wireless Accessories:
Pendant Panic
Transmitters
4 Button Keyfobs
Additional
Wireless Keypad
Magnetic Contacts
for doors/windows
Smoke Detectors
PET Detectors
PIR Detectors
WisDom
Wireless Domestic Security System
Seitenansicht 0
1 2 3 4 5 6 ... 63 64

Inhaltsverzeichnis

Seite 1 - User Manual

User ManualAll rights reserved. No part of this document may be reproduced in anyform without prior written permission from the publisher.5INWSAUM© 8/

Seite 2 - Customer Information

10 WisDom User Manual Chapter 1: Introduction Congratulations on your purchase of the WisDom - Rokonet's Wireless Security System. The WisDom h

Seite 3

WisDom User Manual 11 WisDom Main Features The following table lists the main features of the WisDom: Feature Maximum Capability Total Wireless Zon

Seite 4 - Summary of User Commands 7

12 WisDom User Manual WisDom Architecture Your WisDom controls and monitors a variety of sensors, detectors, and contacts placed throughout the prem

Seite 5

WisDom User Manual 13 Chapter 2: Operating the WisDom The WisDom can easily be operated locally or remotely, with guidance of voice prompts to help

Seite 6

14 WisDom User Manual Voice Messaging Three types of spoken messages are heard when using the WisDom, locally in the premises or remotely to your m

Seite 7 - Summary of User Commands

WisDom User Manual 15 LED Indicators The six LED indicators found at the upper left provide typical system indications, as discussed below. Some ind

Seite 8

16 WisDom User Manual READY LED The Ready LED indicates whether or not the system's intrusion zones are secured and ready to be armed. Conditio

Seite 9 - WisDom User Manual 9

WisDom User Manual 17 TROUBLE LED The Trouble LED indicates troubles in the system. Condition Description RAPID FLASH There is at least one trouble

Seite 10 - Chapter 1: Introduction

18 WisDom User Manual Control Keys The functions of the control keys vary according to the mode being used. The following table lists the functions

Seite 11 - WisDom Main Features

WisDom User Manual 19 Emergency Keys The WisDom has three dedicated sets of emergency keys. Each set of keys must be pressed simultaneously for at l

Seite 12 - WisDom Architecture

2 WisDom User Manual Important Notice This manual is delivered subject to the following conditions and restrictions:  This manual contains proprie

Seite 13 - Operating Tools

20 WisDom User Manual Key User Functions announced messages from the internal speaker. The following speaker levels are available:  “Speaker off

Seite 14 - Voice Messaging

WisDom User Manual 21 Chapter 3: Local Arming and Disarming of the System Arming Arming your system causes the intrusion detectors to trigger an ala

Seite 15 - LED Indicators

22 WisDom User Manual Away Arming Away arming prepares all of the system's intrusion detectors to activate an alarm if violated, and is used w

Seite 16 - BYPASS LED

WisDom User Manual 23 Stay Arming Stay arming activates only perimeter detectors (as defined by your installer), enabling individuals to remain insi

Seite 17 - Keys Functionality

24 WisDom User Manual Partition Arming One of the WisDom’s advantages is its ability to divide the system to up to 3 partitions. Each partition may

Seite 18 - Control Keys

WisDom User Manual 25 NOTE: If defined by your installer press [1/2/3] for quick Away arming or [1/2/3] for quick Stay arming. Examples: To

Seite 19 - Voice Keys

26 WisDom User Manual Disarming Disarming your system causes the detectors not to trigger an alarm when violated. The disarming operation will be f

Seite 20 - LCD Status Display

WisDom User Manual 27 Partition Disarming Partition disarming enables you to disarm individual partitions within an armed system.  To disarm partit

Seite 21 - Disarming of the System

28 WisDom User Manual  To disarm using a duress code: 1) If outside the premises, open an "entry" door. The WisDom beeps, indicating that

Seite 22 -  To away arm:

WisDom User Manual 29 Chapter 4: Remote Phone System Operation The WisDom enables you to operate the system from remote phone. This consists of ini

Seite 23 -  To Stay arm:

WisDom User Manual 3 User Manual

Seite 24 - Partition Arming

30 WisDom User Manual 3) Enter your 2 digit remote access code within 10 seconds. If you wait longer than 10 seconds the system automatically swit

Seite 25

WisDom User Manual 31 Following is the list of remote operations options: Operation Quick Key Combination Arming All Partitions [1][1] Arming sele

Seite 26 -  To disarm the system:

32 WisDom User Manual Two Way Communication The Listen and Talk options enable you to remotely and silently listen in to your premises in order to

Seite 27 -  To disarm partitions:

WisDom User Manual 33 Family Message Center The WisDom enables you to collect voice message from and leave voice message for other users of the sys

Seite 28 -  To silence an alarm:

34 WisDom User Manual Receiving Calls from the System Upon event occurrence, such as alarm activation, the system informs you of security situations

Seite 29 - Operation

WisDom User Manual 35 TIPS: To repeat the Event announcement message, press [#]. To bypass the Event announcement message and go directly to the Ac

Seite 30 - Operations Menu

36 WisDom User Manual Chapter 5: User Codes To perform many of the WisDom functions, a security code (often called a user code) must used. Each ind

Seite 31

WisDom User Manual 37 4) Select [1] Define/Update. 5) Enter the two-digit User Index number to which you want to assign a user code. For example, to

Seite 32 -  To listen and talk:

38 WisDom User Manual Chapter 6: Main User Settings The WisDom comes with a variety of selectable user functions that become available when you ente

Seite 33 - Family Message Center

WisDom User Manual 39 Setting Follow-Me Numbers In the case of an alarm or event, the system can initiate a phone call to a designated telephone or

Seite 34 - Receiving an Event Call

4 WisDom User Manual Summary of User Commands 7 CHAPTER 1: INTRODUCTION... 10 WisDom Main Features ...

Seite 35 - Acknowledge Menu

40 WisDom User Manual ENABLE FM NO 1:REMOTE LISTEN:NENABLE FM NO 1:REMOTE LISTEN:N Select one of the following options to define the permission: Y:

Seite 36 - Chapter 5: User Codes

WisDom User Manual 41 Scheduling Weekly Programs Scheduling weekly programs enables you to automate some system operations. This is performed by def

Seite 37 -  To delete a user code:

42 WisDom User Manual NOTES: 1. When defining the time intervals for each day of the week you can select [8] All to set the same time intervals for

Seite 38

WisDom User Manual 43 Defining a User Limitation Program A user limitation program automatically prevents certain users from disarming the system d

Seite 39 - Setting Follow-Me Numbers

44 WisDom User Manual Select the event for which you want to enable or disable an Announcement message from the following options: [1] Intruder Al

Seite 40 - REMOTE LISTEN:N

WisDom User Manual 45 Premises Operation of the Family Message Center The Family Message Center enables you to play and record a memo message on th

Seite 41 - Scheduling Weekly Programs

46 WisDom User Manual For example, to arm partitions 1 and 2 in a 3-partitioned system with code 1234, you would press the following keys in step 4:

Seite 42

WisDom User Manual 47 Using the Arm / Stay Keys to Program Macro Keys In step 5 of the previous procedure, the and keys are used to toggle betwe

Seite 43

48 WisDom User Manual Chapter 7: Backup Batteries The WisDom has 6 backup batteries that are used in time of main power failure. The batteries can

Seite 44

WisDom User Manual 49 NOTE: Your installer may have locked the battery case by an internal screw. In this case contact your installer to replace the

Seite 45 - Programming Macro Keys

WisDom User Manual 5 Partition Arming...24 Disarming...

Seite 46 -  To program a Macro key:

50 WisDom User Manual Chapter 8: Complete Menu of User Functions Your WisDom comes with a variety of selectable user functions that become available

Seite 47 -  To Activate a Macro key:

WisDom User Manual 51 Quick Key Function Description 2 Follow Me (FM) This option allows to program 2 options regarding the follow Me number: 1) De

Seite 48 - Chapter 7: Backup Batteries

52 WisDom User Manual Quick Key Function Description two minutes during which the installer can enter the programming menu and no report will be ma

Seite 49

WisDom User Manual 53 Quick Key Function Description 6 Information Allows the display of the following information: 1) Service information: Allow

Seite 50 - Functions

54 WisDom User Manual Quick Key Function Description 5 Codes 1 User Codes Allows to define the following user’s parameters: 1) Set code: Sets, c

Seite 51 - Function Description

WisDom User Manual 55 Quick Key Function Description 6 Vacation Enables to define up to 20 vacation periods and the partitions that will be armed

Seite 52 - 52 WisDom User Manual

56 WisDom User Manual Quick Key Function Description 8 Macro Keys 1/2/3 Key [A/B/C] Records a series of commands and assigns them to a function key

Seite 53 - WisDom User Manual 53

WisDom User Manual 57 Appendix A: System Troubles The following table lists some of the possible trouble conditions, their descriptions, and recomme

Seite 54 - 54 WisDom User Manual

58 WisDom User Manual Trouble Description LCD Display Message Response False Code Trouble If enabled by your installer, your system will report a fa

Seite 55

WisDom User Manual 59 Trouble Description LCD Display Message Response WIRELESS ZONES TROUBLES Zone Loss Trouble The system has not received a signa

Seite 56 - 56 WisDom User Manual

6 WisDom User Manual Premises Operation of the Family Message Center... 45 Programming Macro Keys... 45

Seite 57 - Appendix A: System Troubles

60 WisDom User Manual Appendix B: System Sounds In addition to the visual indications provided by the WisDom’s LEDs , your system produces audible a

Seite 58 - Message Response

WisDom User Manual 61 Appendix C: Terms and Definitions There are a few terms with which you should become familiar. Knowing them will help you to b

Seite 59 - WisDom User Manual 59

62 WisDom User Manual Partition: One of the WisDom advantages is its ability to divide any system into a number of partitions. You can think of each

Seite 60 - Appendix B: System Sounds

WisDom User Manual 63 Appendix D: Scheduling Table Use the following table to define each of the weekly programs. Weekly Program No:__________ Progr

Seite 61 - inadvertent alarms

Rokonet Limited Warranty Rokonet Electronics, Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from de

Seite 62

WisDom User Manual 7 Summary of User Commands Away Arm Code > Stay (Home) Arm Code> Partition [1/2/3] Away Arming > [1/2/3]>Code>

Seite 63 - Appendix D: Scheduling Table

8 WisDom User Manual Battery Test >[4]>[Code]> >[1]>[5] Edit User Code >[5]>[Code]> >[1] >[1] Set Time >[6]>[